Minutes of the Forward Endcap EMC Vibe/eZuce meeting, 11th of January 2021, 14:00-15:00

Presence:

  • Bochum: Claudius, Fritz-Herbert, Jan, Miriam, Tobias H., Tobias T., Sebastian, Sven, Tom
  • Basel: -
  • Bonn: Christoph, Tobias S., Ulrike
  • Groningen: -
  • Uppsala: Pawel
  • Giessen: Hans Georg, Markus, Thorsten
  • GSI: -

Recheck of Irradiation Simulations and Bonn Calculations:

  • Summary: All simulations and calculations correct and in accordance
  • Ratio of 10 (0.7 Gy calculated/simulated vs. 7 Gy reading of dosimeter) resulting from small Si-layer in APDs, ICs etc. Dosimeter reading referring to tissue (higher thickness).
  • No consequence for APD irradiation expected: APD samples irradiated with way higher doses without effecting operation (gain, dark current)
  • To be taken into account when irradiating electronic components!

Submodule Production:

  • Next delivery (Thursday this week) submodule transport to Bonn only, FZ Jülich is still in restricted access, start of delivery to Jülich unclear
  • Submodule transport handle return from BN with next delivery

SADC crate power supplies:

  • Final power supply modules not very sophisticated but efficient (design okay)
  • Radiation hardness tests passed
  • Drawback: Low switching frequency requires bigger air coils
  • Fixing central holes of coil toroids also usable for fixing supplies to cooling flanges
  • For thermal tests one should consider 2W/ADC for the final supplies (about 90% efficiency)

Data Concentrators:

  • 1st produced module arrived at Uppsala
  • Start of testing from next week on

-- ThomasHeld - 25 Jan 2021
Topic revision: r1 - 25 Jan 2021, ThomasHeld
 
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding PANDA Wiki? Send feedback
Imprint (in German)
Privacy Policy (in German)