Recheck of Irradiation Simulations and Bonn Calculations:
Summary: All simulations and calculations correct and in accordance
Ratio of 10 (0.7 Gy calculated/simulated vs. 7 Gy reading of dosimeter) resulting from small Si-layer in APDs, ICs etc. Dosimeter reading referring to tissue (higher thickness).
No consequence for APD irradiation expected: APD samples irradiated with way higher doses without effecting operation (gain, dark current)
To be taken into account when irradiating electronic components!
Submodule Production:
Next delivery (Thursday this week) submodule transport to Bonn only, FZ Jülich is still in restricted access, start of delivery to Jülich unclear
Submodule transport handle return from BN with next delivery
SADC crate power supplies:
Final power supply modules not very sophisticated but efficient (design okay)
Radiation hardness tests passed
Drawback: Low switching frequency requires bigger air coils
Fixing central holes of coil toroids also usable for fixing supplies to cooling flanges
For thermal tests one should consider 2W/ADC for the final supplies (about 90% efficiency)