Minutes of the PID-TAG, 16-17h, June, 13 2006, Carsten Schwarz
Thierry Hennino gave a presentation about the possibility to use the DIRC
subsystem for electron-pion separation at low energies, where the EMC-subsystem
has only moderate resolution: Simulations in the "old" PANDA framework show that
at 500
MeV/c the misidentification of an electron as a pion is 2.5%. He pointed
out that it is important to know if the simulations give the right answers. At
1500
MeV/c 66% of the pions have an interaction in the EMC crystals. However, at
BaBar, the pion misidentification turned out to be 5times larger than the
simulated ones. His conclusion was that the DIRC can improve the PID of the EMC
at energies lower than 1GeV.
An discussion about the need of a common plot of separation power for the
subsystems led to the suggestion to put some examples on the wiki pages and to
decide later on about the axis units and standard deviation (2,3,3.5, or 4 sigma)
--
GeorgSchepers - 22 Jun 2006