Minutes of the forward endcap EMC eZuce SRN meeting, 17th of June 2019, 14:00-15:00
Presence:
Basel: -
Bochum: Claudius, Fritz-Herbert, Jan R., Matthias, Tobias H., Malte, Miriam
Bonn: Christoph
Groningen: Myroslav
Stockholm: -
Uppsala: -
Giessen: -
GSI: -
SADC crates:
KVI is still doing design work on the SADC crates, finishing with the cooling flanges
VPTT submodules:
Temperature sensors of all VPTT submodules have been read out: all data compatible with (commercial) reference sensors in the climate chambers
Sensor data will be given to Miriam for a detailed analysis
Sometimes (about 10% of cases) connection problems with the sensor plugs are noticed. Similar observations in Bochum
Tobias (Bonn) presented a comparison between Panda SADC readout and the standard commercial ADC readout of one of the VPTT submoduks in the cosmicstests stand in Bonn: comparable results
Christoph presented the 32 channel HV regulator board (and its dedicated I2C controller borad) that has to undergo radiation hardness tests yet