Objectives of the Shashlyk Calorimeter

  • π/e discrimination
  • energy, position and time measurement

TPR Layout of a Shashlyk module

Number of layers 378
Scintillator layer thickness 1.5 mm
Lead layer thickness 0.275 mm
Effective Moliere radius 59.8 mm
Radiation depth 20 X0
Lateral dimensions 110 x 110 mm2
 
Energy resolution 4.% / sqrt(E)
Time resolution 100 ps / sqrt(E)

Results of simulations

Piotr Hawranek performed simulations of the calorimeter electron/pion separation (Panda meeting Dec'06). He used the so-called old code. Simulation comprised:

  • π- and e- beams of 1 and 5 GeV/c momentum
  • setup with modules of various lateral dimensions

Detector response and cuts imposed in order to select electrons of 5 GeV/c momentum in the 110 x 110 mm2 modules are shown as an example of the procedure.

Results of the simulations are summarised in the table below.

Module size e- identified π- identified as e-
30 x 30 mm2 84.6% 0.2%
55 x 55 mm2 93.3% 0.4%
110 x 110 mm2 97.4% 0.8%

Module size e- identified π- identified as e-
55 x 55 mm2 96.2% 4.7%
110 x 110 mm2 98.1% 8.7%

It should be stressed here, that the analysis procedure was rather rough. Certainly, application of a more sophisticated tools (e.g. Bayes theorem) could improve the results. The trend, however, is clear already from the presented numbers.

-- AleksandraWronska - 26 Apr 2006

Topic attachments
I Attachment Action Size Date Who Comment
ecal.gifgif ecal.gif manage 9.1 K 26 Apr 2006 - 07:58 AleksandraWronska pi/e separation
This topic: Tagpid/Pandatagpid > WebHome > TasksandResults > ForwardCalorimeter
Topic revision: 26 Apr 2006, AleksandraWronska
 
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.