PANDA Detector Control System

>
>

PANDA Detector Control System

 
Line: 29 to 31
 

The autonomy of each PANDA DCS partition (Fig. 2) implies that the partition should be self-controllable. This means that, specific slow control software, tailored to configure, monitor and control the hardware devices belonging to the partition, is required. Moreover, the partition specific software must be capable to share data with the supervisory layer.
Changed:
<
<
In order to ensure compatible data sharing between the DCS supervisory layer and DCS partition, an EPICS Process Variable Gateway is required to be implemented by each PANDA SC partition. Additionally, the PV Gateway will provide access rights administration and subnet interface.
>
>
In order to ensure compatible data sharing between the DCS supervisory layer and DCS partition, an EPICS Process Variable Gateway is required to be implemented by each PANDA DCS partition. Additionally, the PV Gateway will provide access rights administration and subnet interface.
 
Changed:
<
<
The SC operation of each partition will be performed from a dedicated graphical user interface (GUI). The interface should ensure the accurate and safe operation of the partition hardware. The complete interface, or part of it, will be embedded in the PANDA supervisory software.
>
>
The SC operation of each partition will be performed from a dedicated graphical user interface (GUI). The interface must ensure the accurate and safe operation of the partition hardware. The complete interface, or part of it, will be embedded in the PANDA supervisory software.
 
Changed:
<
<
At the moment, the state of the art user interface to EPICS is supported by the Control System Studio (CSS) framework. The technical design of PANDA SC system is planned to provide a set of guidelines for naming conventions, and graphical interface look and feel, in order to guarantee the similarity of the independent developed modules and to simplify the integration.
>
>
At the moment, the state of the art user interface to EPICS is supported by the Control System Studio (CSS) framework. The technical design of PANDA DCS is planned to provide a set of guidelines for naming conventions, and graphical interface look and feel, in order to guarantee the similarity of the independent developed modules and to simplify the integration.
 

The outcome of putting all the above requirements together is a PANDA DCS architecture based on a three-layer design – Supervisory, Control and Field layers. The highest level is the Supervisory one. The Control Layer is in the middle and it is the level where all the PANDA DCS partitions are connected. The Field Layer is embedded in each PANDA DCS Partition, and is made of all the devices and sensors used to monitor and control the sub-sytem.
Line: 43 to 45
 

PANDA DCS Partitions

Changed:
<
<
PANDA DCS partitions are summarized in the table below:
PANDA Sytem DCS Partition
Magnets Solenoid
Dipole
Targets Pellet Target
Cluster Target
Beam line and Interaction Region
Silicon Detectors Pixel & Strip
Luminosity
Trackers Straw Tube
Endcap GEM
Forward trackers
EMC EMC
Muon system Muon system
Hypernuclei equipment Hypernuclei
  Services
>
>
PANDA DCS partitions together with the DCS coordinators are summarized in the table below:
PANDA Sytem DCS Partition DCS Coordinators
<-- -->
Sorted ascending
Charged Particle ID Barrel DIRC Andreas Gerhardt
Trackers Endcap GEM Bernd Voss
Targets Pellet Target Bogdan Zwieglinski
Targets Cluster Target Bogdan Zwieglinski
Targets Beam line and Interaction Region Bogdan Zwieglinski
Silicon Detectors Luminosity Florian Feldbauer
Silicon Detectors Pixel & Strip Harald Kleines
Magnets Solenoid Jost Luehning
Magnets Dipole Jost Luehning
Trackers Straw Tube Mario Bragadireanu
Trackers Forward trackers t.b.a.
Charged Particle ID Endcap Cherenkov t.b.a.
Charged Particle ID Forward RICH t.b.a.
Charged Particle ID SciTil (Barrel TOF) t.b.a.
Charged Particle ID FTOF t.b.a.
Muon system Muon system t.b.a.
Hypernuclei equipment Hypernuclei t.b.a.
  Services t.b.a.
Electromagnetic Calorimeter Electromagnetic Calorimeter Thomas Held
  The team taking responsibility for the controls of a PANDA DCS partition is expected to provide:
  • implementation of controls for the hardware devices belonging to the Field Layer of the partition;
  • the software running on the Control Layer of the partition;
Line: 95 to 102
 

Contacts

Changed:
<
<
The PANDA SC subgroup has been formed in 2007. The subgroup is basically made by people, from different PANDA collaborating institutions, involved in the slow controls of the experiment, chaired by the SC sub-system manager. The most up-to-date list of DCS members can be found here.

The subgroup chairman at this time is MarioBragadireanu . Past chairman: DanProtopopescu .
>
>
The PANDA SC subgroup has been formed in 2007. The subgroup is basically made by people, from different PANDA collaborating institutions, involved in the slow controls of the experiment, chaired by the SC sub-system manager. The most up-to-date list of DCS members can be found here. The present subgroup chairman is Mario Bragadireanu.
 
Changed:
<
<
Our mailing list is called panda-dcs@gsi.de. hand.gif GSI Listserv
>
>
The DCS mailing list is panda-dcs@gsi.de.
 

META FILEATTACHMENT attachment="PandaCentralDCS.png" attr="" comment="" date="1413099588" name="PandaCentralDCS.png" path="PandaCentralDCS.png" size="71653" user="MarioBragadireanu" version="1"
META FILEATTACHMENT attachment="PandaDCSPartition.png" attr="" comment="" date="1413101670" name="PandaDCSPartition.png" path="PandaDCSPartition.png" size="68318" user="MarioBragadireanu" version="2"
Revision 4
12 Oct 2014 - Main.MarioBragadireanu
Line: 1 to 1
  -- MarioBragadireanu - 12 Oct 2014

Welcome to the home of PANDA DCS wiki.

PANDA Detector Control System

Added:
>
>
 
Deleted:
<
<
 
Changed:
<
<
    • Latest news
    • Meetings
    • Forum

PANDA DCS Technical Design

>
>

PANDA DCS Technical Design

 

The present structure of PANDA experiment involves several sub-detectors and sub-systems (Fig.1). The Slow Controls (SC) of each PANDA sub-detector and sub-system are planned to be monitored and controlled from a supervisory software application.
Line: 38 to 40
  PandaDCSLayers.png

Because the device driver software support in EPICS is limited, the software development tools used to control the lowermost layer (Field Layer) are at the free choice of the developer. The only constrain here is that the software must be integrated in the control layer with the EPICS system. However, the recommendation is that the developer, in the early stages of design, should try implement, were is possible, the same hardware and software, with EPICS support, realized by other PANDA sub-systems.
Added:
>
>

PANDA DCS Partitions

 
Changed:
<
<

PANDA DCS Technical Support

Hardware & Software

>
>
PANDA DCS partitions are summarized in the table below:
PANDA Sytem DCS Partition
Magnets Solenoid
Dipole
Targets Pellet Target
Cluster Target
Beam line and Interaction Region
Silicon Detectors Pixel & Strip
Luminosity
Trackers Straw Tube
Endcap GEM
Forward trackers
EMC EMC
Muon system Muon system
Hypernuclei equipment Hypernuclei
  Services
The team taking responsibility for the controls of a PANDA DCS partition is expected to provide:
  • implementation of controls for the hardware devices belonging to the Field Layer of the partition;
  • the software running on the Control Layer of the partition;
  • the partition GUI software;
  • the autonomous operation of the partition.

The PANDA DCS sub-system manager is responsible with:
  • the preparation of DCS technical design;
  • monitor (and guarantee) the implementation of the DCS technical design;
  • the integration of the DCS partitions in the supervisory layer;
  • organize the development of the DCS supervisory software.

PANDA DCS Technical Support

Hardware & Software
 
  • SupportedHardware is a wiki describing the proposed/tested/supported sensor/control hardware for the PANDA DCS. Early contributions have the chance to set the standards and significantly help other detector subgroups. Please contribute.
  • PANDA CSS
Changed:
<
<

Process Variables Naming Convention

>
>
Process Variables Naming Convention
 

The naming convention for PANDA slow control process variables is outlined in this wiki: PVNamingConventions. We recommend implementing these rules early, to avoid later confusion.
Changed:
<
<

Tutorials & Examples

>
>

Tutorials & Examples

 
Changed:
<
<

Contacts

>
>

Information exchange

News
Meetings
  • Next PANDA DCS session: parallel session @ PANDA LI Collaboration Meeting
  • The master archive with presentations from all our subgroup meetings is here: TalksArchive. Please attach your talks using your account, such that the author name is visible and easy to search for. Preferred format is pdf.
Forum

The subgroup forum is located here.

Contacts

 
Changed:
<
<
According to the PANDA Technical Board managerial chart, the Detector Control sub-system is under the responsibility of a sub-system manager. In 2007, the PANDA SC subgroup has been formed. The subgroup is basically made by people, from different PANDA collaborating institutions, involved in the slow controls of the experiment, chaired by the SC sub-system manager. The most up-to-date list of DCS members can be found here.
>
>
The PANDA SC subgroup has been formed in 2007. The subgroup is basically made by people, from different PANDA collaborating institutions, involved in the slow controls of the experiment, chaired by the SC sub-system manager. The most up-to-date list of DCS members can be found here.
 

The subgroup chairman at this time is MarioBragadireanu . Past chairman: DanProtopopescu .
Added:
>
>
Our mailing list is called panda-dcs@gsi.de. hand.gif GSI Listserv
 
META FILEATTACHMENT attachment="PandaCentralDCS.png" attr="" comment="" date="1413099588" name="PandaCentralDCS.png" path="PandaCentralDCS.png" size="71653" user="MarioBragadireanu" version="1"
META FILEATTACHMENT attachment="PandaDCSPartition.png" attr="" comment="" date="1413101670" name="PandaDCSPartition.png" path="PandaDCSPartition.png" size="68318" user="MarioBragadireanu" version="2"
META FILEATTACHMENT attachment="PandaDCSLayers.png" attr="" comment="" date="1413105331" name="PandaDCSLayers.png" path="PandaDCSLayers.png" size="113227" user="MarioBragadireanu" version="1"
Revision 3
12 Oct 2014 - Main.MarioBragadireanu
Line: 1 to 1
  -- MarioBragadireanu - 12 Oct 2014

Welcome to the home of PANDA DCS wiki.

PANDA Detector Control System

Changed:
<
<

PANDA DCS Technical Design

>
>

PANDA DCS Technical Design

 

The present structure of PANDA experiment involves several sub-detectors and sub-systems (Fig.1). The Slow Controls (SC) of each PANDA sub-detector and sub-system are planned to be monitored and controlled from a supervisory software application.
Line: 19 to 27
 

The autonomy of each PANDA DCS partition (Fig. 2) implies that the partition should be self-controllable. This means that, specific slow control software, tailored to configure, monitor and control the hardware devices belonging to the partition, is required. Moreover, the partition specific software must be capable to share data with the supervisory layer.
Changed:
<
<
In order to ensure compatible data sharing between the SC supervisory layer and SC partition, an EPICS Process Variable Gateway is required to be implemented by each PANDA SC partition. Additionally, thePV Gateway will provide access rights administration and subnet interface.
>
>
In order to ensure compatible data sharing between the DCS supervisory layer and DCS partition, an EPICS Process Variable Gateway is required to be implemented by each PANDA SC partition. Additionally, the PV Gateway will provide access rights administration and subnet interface.
 

The SC operation of each partition will be performed from a dedicated graphical user interface (GUI). The interface should ensure the accurate and safe operation of the partition hardware. The complete interface, or part of it, will be embedded in the PANDA supervisory software.
Line: 30 to 38
  PandaDCSLayers.png

Because the device driver software support in EPICS is limited, the software development tools used to control the lowermost layer (Field Layer) are at the free choice of the developer. The only constrain here is that the software must be integrated in the control layer with the EPICS system. However, the recommendation is that the developer, in the early stages of design, should try implement, were is possible, the same hardware and software, with EPICS support, realized by other PANDA sub-systems.
Changed:
<
<

Contacts

>
>

PANDA DCS Technical Support

Hardware & Software

  • SupportedHardware is a wiki describing the proposed/tested/supported sensor/control hardware for the PANDA DCS. Early contributions have the chance to set the standards and significantly help other detector subgroups. Please contribute.
  • PANDA CSS

Process Variables Naming Convention

The naming convention for PANDA slow control process variables is outlined in this wiki: PVNamingConventions. We recommend implementing these rules early, to avoid later confusion.

Tutorials & Examples

Contacts

According to the PANDA Technical Board managerial chart, the Detector Control sub-system is under the responsibility of a sub-system manager. In 2007, the PANDA SC subgroup has been formed. The subgroup is basically made by people, from different PANDA collaborating institutions, involved in the slow controls of the experiment, chaired by the SC sub-system manager. The most up-to-date list of DCS members can be found here.

The subgroup chairman at this time is MarioBragadireanu . Past chairman: DanProtopopescu .
 

META FILEATTACHMENT attachment="PandaCentralDCS.png" attr="" comment="" date="1413099588" name="PandaCentralDCS.png" path="PandaCentralDCS.png" size="71653" user="MarioBragadireanu" version="1"
META FILEATTACHMENT attachment="PandaDCSPartition.png" attr="" comment="" date="1413101670" name="PandaDCSPartition.png" path="PandaDCSPartition.png" size="68318" user="MarioBragadireanu" version="2"
Revision 2
12 Oct 2014 - Main.MarioBragadireanu
Line: 1 to 1
  -- MarioBragadireanu - 12 Oct 2014
Added:
>
>

Welcome to the home of PANDA DCS wiki.
 

PANDA Detector Control System

Added:
>
>

PANDA DCS Technical Design

 

The present structure of PANDA experiment involves several sub-detectors and sub-systems (Fig.1). The Slow Controls (SC) of each PANDA sub-detector and sub-system are planned to be monitored and controlled from a supervisory software application.
Changed:
<
<
PandaCentralDCS.png
>
>
PandaCentralDCS.png

In the past, an evaluation of several SCADA development packages, PVSS, LabView, EPICS, was performed by a PANDA slow controls subgroup and the EPICS package was selected to be the main SC software development tool.
 
Changed:
<
<
In the past, an evaluation of SCADA development packages, PVSS, LabView, EPICS, was performed by a PANDA slow controls subgroup and the EPICS package was selected to be the main SC software development tool.
>
>
Due to the anticipated complexity of the whole PANDA DCS and the expected staged assembly of PANDA detector, the DCS is highly needed to be modular and scalable. In order to accomplish this, each PANDA sub-detector or sub-system is envisaged to be basically autonomous but manageable from a supervisory layer.
 
Changed:
<
<
Due to the anticipated complexity of the whole PANDA SC and the expected staged assembly of PANDA detector, the SC system is highly needed to be modular and scalable. In order to accomplish this, each PANDA sub-detector or sub-system is envisaged to be basically autonomous but manageable from a supervisory layer.
>
>
PandaDCSPartition.png
 
Changed:
<
<
The autonomy of each PANDA SC partition (Fig. 2) implies that the partition should be self-controllable. This means that, specific slow control software, tailored to configure, monitor and control the hardware devices belonging to the partition, is required. Moreover, the partition specific software must be capable to share data with the supervisory layer.
>
>
The autonomy of each PANDA DCS partition (Fig. 2) implies that the partition should be self-controllable. This means that, specific slow control software, tailored to configure, monitor and control the hardware devices belonging to the partition, is required. Moreover, the partition specific software must be capable to share data with the supervisory layer.
 
Changed:
<
<
In order to ensure compatible data sharing between the SC supervisory layer and SC partition, an EPICS Gateway is required to be implemented by each PANDA SC partition. Additionally, the above gateway will provide access rights administration and subnet interface.
>
>
In order to ensure compatible data sharing between the SC supervisory layer and SC partition, an EPICS Process Variable Gateway is required to be implemented by each PANDA SC partition. Additionally, thePV Gateway will provide access rights administration and subnet interface.
 

The SC operation of each partition will be performed from a dedicated graphical user interface (GUI). The interface should ensure the accurate and safe operation of the partition hardware. The complete interface, or part of it, will be embedded in the PANDA supervisory software.

At the moment, the state of the art user interface to EPICS is supported by the Control System Studio (CSS) framework. The technical design of PANDA SC system is planned to provide a set of guidelines for naming conventions, and graphical interface look and feel, in order to guarantee the similarity of the independent developed modules and to simplify the integration.
Added:
>
>
The outcome of putting all the above requirements together is a PANDA DCS architecture based on a three-layer design – Supervisory, Control and Field layers. The highest level is the Supervisory one. The Control Layer is in the middle and it is the level where all the PANDA DCS partitions are connected. The Field Layer is embedded in each PANDA DCS Partition, and is made of all the devices and sensors used to monitor and control the sub-sytem.

PandaDCSLayers.png
  Because the device driver software support in EPICS is limited, the software development tools used to control the lowermost layer (Field Layer) are at the free choice of the developer. The only constrain here is that the software must be integrated in the control layer with the EPICS system. However, the recommendation is that the developer, in the early stages of design, should try implement, were is possible, the same hardware and software, with EPICS support, realized by other PANDA sub-systems.
Added:
>
>

Contacts

 

META FILEATTACHMENT attachment="PandaCentralDCS.png" attr="" comment="" date="1413099588" name="PandaCentralDCS.png" path="PandaCentralDCS.png" size="71653" user="MarioBragadireanu" version="1"
META FILEATTACHMENT attachment="PandaDCSPartition.png" attr="" comment="" date="1413101670" name="PandaDCSPartition.png" path="PandaDCSPartition.png" size="68318" user="MarioBragadireanu" version="2"
Added:
>
>
META FILEATTACHMENT attachment="PandaDCSLayers.png" attr="" comment="" date="1413105331" name="PandaDCSLayers.png" path="PandaDCSLayers.png" size="113227" user="MarioBragadireanu" version="1"
 
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding PANDA Wiki? Send feedback
Imprint (in German)
Privacy Policy (in German)