Minutes of the forward endcap EMC Vibe/eZuce meeting, 16th of August 2019, 14:00-14:50 |
> > |
Minutes of the forward endcap EMC Vibe/eZuce meeting, 26th of August 2019, 14:00-14:50 |
|
Presence:
- Basel: -
- Bochum: Matthias, Thorsten, Tom
|
|
-
- The 12 GeV Panda FWEC EMC single crystal energy maximum is probably detetcable with all channels (detailed analysis follows)
- The spread of channel responses (inter crystal and between APDs on one crystal) is as expected and acceptable
- Second APD submodule is going to cosmics test stand soon
|
|
< < |
-
- Noise figures of both submodules comparable in terms of sigma, but a closer look to the shape (non guassian contribution) is needed as this indicates the occurance of pickup noise
- Annealing LED cabling appears to be short (probably not too short but close to limit) - does this come from cable routing through the aluminum tube (as tested for one of the two submodules built)?
|
> > |
-
- Noise figures of both submodules comparable in terms of sigma, but a closer look to the shape (non gaussian contribution) is needed as this indicates the occurance of pickup noise
- Annealing LED cabling appears to be short (probably not too short but close to limit) - does this come from cable routing through the aluminum tube (as tested for one of the two submodules built)? Checked: no!
|
|
- The signal labeling/color coding should be improved: ideal would be an omission of the shrinking tube as it hinders cabling to the PCB and preferred is a labeling that does not move along the signal cable
- We therefore will change to the newly tested paper cable labels that we print on our own and that include the color coding by colored prints
VPTT-Submodules: |
|
-
- He presented results of scans of the alveole surface
- All submodules turn out to be between 1.6 and 2.2 mm longer than expected from an existing CAD model
- These numbers agree with the caliper measurements made on the submodules after finishing in Bochum
|
|
< < |
-
-
- It is not yet clear whether the CAD model is outdated (maybe does not contain the capusles?)
|
> > |
-
-
- It is not yet clear whether the CAD model is outdated (maybe does not contain the capsules?)
|
|
-
-
- Is the spread of elongation (1.6 - 2.2 mm) compatible with the thickness variation of the VPTT capsules?
- Christian also presented x-ray images of a submodule showing about 0.4 (0.6) mm free space between crystal front faces and carbon inner (outer) fibre front
|
|
< < |
-
-
- Does the difference of (1.6/2.2 - 0.6) mm = (1 - 1.6) mm correspond to the VPTT capsule thickness?
|
> > |
-
-
- Does the difference of (1.6/2.2 - 0.6) mm = (1 - 1.6) mm correspond to the VPTT capsule thicknesses?
|
|
-
- We therefore need to measure the resulting maximum distances of submodules (corners) to the backplate (minimum free space to the front lid)
- Has there been a redesign (decrease of height) in the interface pieces in order to account for the elongation of the submodules by the introduction of the capsules?
|
|
< < |
|
|