Temperature and Humidity Monitoring Board for PANDA

Temperature and Humidity Monitoring Board for PANDA

  

The THMP has been developed to monitor the temperature and humidity inside the electromagnetic calorimeter (EMC) of the PANDA target spectrometer. Therefore it has 64 channels and is designed to read out PT100 temperature sensors and HIH-4000 humidity sensors. This device has been constructed to operate in a temperature range from -30 °C to +30 °C. To cover the whole temperature range of the EMC, the measurement range will also be from -30 °C to +30 °C with a resolution of 0.05 K. The relative humidity (RH) can be measured in the range from 0 to 100% RH with an accuracy of 3.5%. For the read-out of this device a CAN interface is foreseen.

The THMP has been developed to monitor the temperature and humidity inside the electromagnetic calorimeter (EMC) of the PANDA target spectrometer. Therefore it has 64 channels and is designed to read out PT100 temperature sensors and HIH-4000 humidity sensors. This device has been constructed to operate in a temperature range from -30 °C to +30 °C. To cover the whole temperature range of the EMC, the measurement range will also be from -30 °C to +30 °C with a resolution of 0.05 K. The relative humidity (RH) can be measured in the range from 0 to 100% RH with an accuracy of 3.5%. For the read-out of this device a CAN interface is foreseen.

  

The THMP should fulfill the environmental requirements of operating in the cooled area of the EMC. Different tests were carried out to verify this.

The THMP should fulfill the environmental requirements of operating in the cooled area of the EMC. Different tests were carried out to verify this.

  

-- FlorianFeldbauer - 07 Dec 2009

-- FlorianFeldbauer - 07 Dec 2009

IAttachmentActionSorted ascendingSizeDateWhoComment
ThmpReport_Rev1.1.pdfpdfThmpReport_Rev1.1.pdfmanage 1981.0 K 06 Dec 2009 - 18:21PatrickFriedel Documentation of the development of the THMP
IAttachmentActionSorted ascendingSizeDateWhoComment
ThmpReport_Rev1.1.pdfpdfThmpReport_Rev1.1.pdfmanage 1981.0 K 06 Dec 2009 - 18:21PatrickFriedel Documentation of the development of the THMP
r8 - 15 Jan 2010 - 12:42 - FlorianFeldbauer r7 - 07 Dec 2009 - 08:27 - FlorianFeldbauer

Revision r8 - 15 Jan 2010 - 12:42 - FlorianFeldbauer
Revision r7 - 07 Dec 2009 - 08:27 - FlorianFeldbauer
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding PANDA Wiki? Send feedback
Imprint (in German)
Privacy Policy (in German)