Powered by Foswiki, The Free and Open Source Wiki
EMC  THMP (compare)

Difference: THMP (r5 vs. r4)

r5 - 30 Nov 2009 - 14:11 - PatrickFriedel r4 - 17 Nov 2009 - 14:04 - FlorianFeldbauer

Temperature and Humidity Monitoring Board for PANDA

Temperature and Humidity Monitoring Board for PANDA

  

The THMPhas been developed to monitor the temperature and humidity inside the electromagnetic calorimeter (EMC) of the PANDA target spectrometer. Therefore it has 64 channels and is designed to read out PT100 temperature sensors and HIH-4000humidity sensors. This device has been constructed to operate in a temperature range from -30 °C to +30 °C. To cover the whole temperature range of the EMC the measurement range will also be from -30 °C to +30 °C with a resolution of 0.05 K. The relative humidity (RH) can be measured in a range from 0 to 100% RH with an accuracy of 3.5%. For the read-out of this device a CAN interface is foreseen.

The THMPis developed to monitor the temperature and humidity inside the electromagnetic calorimeter (EMC) of the PANDA target spectrometer. Therefore it has 64 channels and is designed to read-out PT100 temperature sensors and HIH-4000humidity sensors. This device is constructed to operate in a temperature range from -30 °C to +30 °C. To cover the whole temperature range of the EMC the measurement range will be also from -30 °C to +30 °C with a resolution of 0.05 K. The relative humidity (RH) can be measured in a range from 0 to 100% RH with an accuracy of 3.5%. For the read-out of this device a CAN interface is foreseen.

  

The THMP should fulfill the environmental requirements of operating in the cooled area of the EMC. Different tests were carried out to verify this.

  

-- FlorianFeldbauer, PatrickFriedel - 30 Nov 2009

-- FlorianFeldbauer- 17 Nov 2009

IAttachmentActionSizeDateWhoComment
ThmpReport_Rev1.0.pdfpdfThmpReport_Rev1.0.pdfmanage 1980.1 K 17 Nov 2009 - 14:03FlorianFeldbauer Documentation of the development of the THMP
IAttachmentActionSizeDateWhoComment
ThmpReport_Rev1.0.pdfpdfThmpReport_Rev1.0.pdfmanage 1980.1 K 17 Nov 2009 - 14:03FlorianFeldbauer Documentation of the development of the THMP
r5 - 30 Nov 2009 - 14:11 - PatrickFriedel r4 - 17 Nov 2009 - 14:04 - FlorianFeldbauer